Technical requirements:
1.Coating requirements:1560.05nm filter coatings;operating angle:0°~2°
2.Pass band:center wavelength:1563.05nm±2nm;FWHM≤20NM;T>92%@1563.05nm±1nm
3.Stop band:Within the stop band (400nm~1800nm wave band,excluding the pass band):Tavg<0.2%;T<0.01%@1540.56nm ±1nm (0D4)
4.surface accuracy requirements:Testing is done with an interferometer;λ=632.8nm.
Uncoated condition:Transmitted wave aberration (including power):superior to 1/60 λRMS;two surface accuracy (including power);:superior to 3λPV
Coated condition:Transmitted wave aberration (including power):superior to 1/40 λRMS (testing can be done with a wavefront sensor.In the case of a subaperture of φ8.8mm:RMS:superior toλ/97;λ=1563nm;4apertures at least);parallelism:superior to 0.01mm.
Product dimensions
|
Nd
|
/
|
Vd
|
/
|
Optical uniformity
|
H2
|
Optical absorptivity
|
1C
|
Stress birefringence
|
2
|
Fringe intensity
|
1C
|
Extent of bubble
|
3
|
Product dimensions
|
|
R1
|
R1
|
Specimen precision △R
|
A
|
A
|
Radius deviation N
|
/
|
/
|
Partial deviation △N
|
/
|
/
|
Eccentricity c
|
/
|
/
|
Surface finishment MIL
|
Ⅲ
|
Ⅲ
|
Clear aperture Do
|
Ф14.1
|
Ф14.1
|